TANGO
Device Server



Bergoz DCCT controller
Properties Description

DCCTBergoz Class

Revision: release_1_0_0 - Author: siraut






Device Properties
Property name
Property type
Description
DIODeviceName Tango::DEV_STRING Name of the underlying DIO device [DIO_7432 or compatible - no default value]
DIODeviceRangeCtrlPins Array of string Two pins must be specified in order to define the range (2A/200mA) : "RANGE/10" and "RANGE/100"
Format of this property is :
RANGE/10:PxY
RANGE/100:PzW
[No default value]
DIODeviceTestCtrlPin Tango::DEV_STRING Specifies the pin that is used to write the test mode (PxY). [No default value]
DIODeviceRedLionCtrlLine Tango::DEV_STRING DIO device's pin (PxY) associated with the DCCT range [no default value]
FullScaleRange Tango::DEV_STRING The DCCT range. Should be one of he following strings: "2A" or "200mA". No default value.
TestMode Tango::DEV_STRING Test mode can be active (set this property to ACTIVE) or inactive (set this property to INACTIVE






Device Properties Default Values:
Property Name Default Values
DIODeviceName No default value
DIODeviceRangeCtrlPins No default value
DIODeviceTestCtrlPin No default value
DIODeviceRedLionCtrlLine No default value
FullScaleRange No default value
TestMode No default value



There is no Class properties.