TANGO
Device Server



DataFitter
Properties Description

DataFitter Class

Revision: release_3_0_6 - Author: julien_malik






Device Properties
Property name
Property type
Description
DeviceAttributeNameX Tango::DEV_STRING Path to the attribute X of the device providing the X values of the spectrum.
DeviceAttributeNameY Tango::DEV_STRING Path to the attribute Y of the device providing the Y values of the spectrum.
DeviceAttributeNameSigma Tango::DEV_STRING Path to the attribute Sigma of the device providing the Sigma values of the spectrum.
UseSigma Tango::DEV_BOOLEAN This property indicate of sigma values are provided.
AutoSaveData Tango::DEV_BOOLEAN This porperty is used to define if the experimental data and the fitted data must be saved after each fit If this property is set to : true, the properties : FilePath (path to the directory to save the data) ExperimentalDataFileName (filename for the experimental data file) FittedDataFileName (filename for the fitted data file) each filename will be postfixed by a number to avoid losing an old file
FilePath Tango::DEV_STRING The path to the directory where to save the data
ExperimentalDataFileName Tango::DEV_STRING The filename to use to save the experimental data This filename will be postfixed by _number.txt
FittedDataFileName Tango::DEV_STRING The filename to used to save the fitted data This filename will be postfixed by _number.txt






Device Properties Default Values:
Property Name Default Values
DeviceAttributeNameX No default value
DeviceAttributeNameY No default value
DeviceAttributeNameSigma No default value
UseSigma false
AutoSaveData false
FilePath No default value
ExperimentalDataFileName No default value
FittedDataFileName No default value



There is no Class properties.