TANGO
Device Server



DOF Power Supply
Device Attributes Description

DofPowerSupply Class

Revision: release_1_4_2 - Author: langlois

Scalar Attributes
Attribute name
Data Type
R/W Type
Expert
voltagePeakValue: Voltage peak value from the Power Supply (16bits 0-5V for 0-15V full Scale)
read value: value calculated from spectrum voltage read value
write value: value used to generate voltage spectrum write value
DEV_DOUBLE
READ_WRITE
No
currentPeakValue: Current peak value from the Power Supply (16bits 0-10V for 0-200A full Scale)
read value: value calculated from spectrum current read value
write value: value used to generate current spectrum write value
DEV_DOUBLE
READ
No
timingTriggerDelay: Delay of the trigger coming from Timing.
DEV_DOUBLE
READ_WRITE
Yes
timingTriggerStatus: Status of the trigger coming from Timing:
0 -> none
1 -> present
DEV_BOOLEAN
READ
Yes
timingEventNumber: Timing Event Number:
0 -> OFF
1 -> Precharge
2 -> Injection
3 -> Extraction...
DEV_LONG
READ_WRITE
Yes
localTriggerDelay: Delay of the local trigger
DEV_DOUBLE
READ_WRITE
Yes
localTriggerStatus: Status of the trigger coming from Timing:
0 -> none
1 -> present
DEV_BOOLEAN
READ
No
frequency: Sampling Frequency.
DEV_DOUBLE
READ_WRITE
No
halfSineDuration: halfSineDuration in secondes:
secondes = frequency / bufferdepth
DEV_DOUBLE
READ_WRITE
No
bufferDepth: Buffer Depth
DEV_LONG
READ_WRITE
No
processDefault: Default in the PLC Process, read on the CPCI crate via 7432 board. (a wire goes from PLC to 7432).
0-> Ok
1-> Default
DEV_SHORT
READ
No
hTStatus: ON/OFF status of the HT:
1 -> HT is ON
0 -> HT is OFF
DEV_SHORT
READ
No
continuousCVStatus: Status of the Continuous Current/Voltage
0 -> Current command
1 -> Voltage command
If this error occur, check that there is some Current (Local Button)
The line for the continuousCVStatus is set by DIOCCStatusLine property.
Don't forget to Acknowledge this error with the Command AcknowledgeErrors.
DEV_SHORT
READ
No
overVoltageProtection: Over Load Status (Over Voltage Protection : OVP)
0 -> ok
1 -> default (over voltage)
The line for the overVoltageProtection is set by DIOOVPStatusLine property.
Don't forget to Acknowledge this error with the Command AcknowledgeErrors.
DEV_SHORT
READ
No
waveformGenerationStatus: Status of the Waveform Generation:
0 -> OFF
1 -> ON
DEV_BOOLEAN
READ
No
powerSupplyStatus: Etat de la commande locale de mise sous tension de l'alimentation.
0 -> OFF
1 -> ON
DEV_SHORT
READ
No





Spectrum Attributes
Attribute name
Data Type
X Data Length
Expert
voltageSpectrum: Voltage Power Supply Readback with the CPCI 2005 (16bits 0-10V for 0-15V full Scale)
DEV_DOUBLE
10000
No
setVoltageSpectrum: View of the set Voltage Spectrum (applied to the Power Supply).
DEV_DOUBLE
10000
No
currentSpectrum: Current Power Supply Read with the CPCI 2005 (16bits 0-5V for 0-200A full Scale)
DEV_DOUBLE
10000
No