TANGO
Device Server



Power Supply of a Kicker
Device Attributes Description

KickerPowerSupply Class

Revision: release_1_5_1 - Author: langlois

Scalar Attributes
Attribute name
Data Type
R/W Type
Expert
voltage: Write: Voltage order
Read: Effective Voltage order (ie: what is taken into account by the power supply).
DEV_DOUBLE
READ_WRITE
No
current: Write: Current order
Read: Effective Current order (ie: what is taken into account by the power supply).
DEV_DOUBLE
READ_WRITE
No
setCurrentStatus: Set Current Status:
0 -> Set Current is OK
1 -> Set Current is NULL -> retry to set the current
DEV_SHORT
READ
No
triggerDelay: Delay time for the HT Trigger (3 Hz comming from Linac).
DEV_DOUBLE
READ_WRITE
Yes
triggerDuration: Duration time of the HT Trigger (3 Hz comming from Linac).
DEV_DOUBLE
READ_WRITE
Yes
acqTriggerDelay: Delay time for the Analog Input Acquisition Trigger (3 Hz comming from Linac).
DEV_DOUBLE
READ_WRITE
Yes
acqTriggerDuration: Duration time of the Analog Input Acquisition Trigger (3 Hz comming from Linac).
DEV_DOUBLE
READ_WRITE
Yes
processDefault: Default in the PLC Process, read on the CPCI crate via 7432 board. (a wire goes from PLC to 7432).
0-> Ok
1-> Default
DEV_SHORT
READ
No
interlockStatus: Status of the Interlock:
0 -> valid (no Interlock)
1 -> inhibit (Interlock occured).
DEV_SHORT
READ
Yes
miscDefaultStatus: Status of Miscellaneous Default:
0 -> Ok
1 -> Default
DEV_SHORT
READ
Yes
overCurrentStatus: Status of the OverCurrent:
0 -> Ok
1 -> Default
DEV_SHORT
READ
Yes
controlModeStatus: Status of the Control Mode:
0 -> local
1 -> remote
DEV_SHORT
READ
Yes
supplyNetworkStatus: Status of the Supply Network:
0 -> Ok
1 -> Default
DEV_SHORT
READ
Yes
endLoadStatus: Status of the End Load
0 -> End Load
1 -> Loading
DEV_SHORT
READ
Yes
hTValidationStatus: Status of the HT Validation:
0-> none
1-> present
DEV_SHORT
READ
Yes
hTStatus: Status of the HT Power Supply:
0 -> OFF
1 -> ON
DEV_SHORT
READ
Yes
triggerStatus: Status of the HT Triggering:
0-> none
1-> present
DEV_SHORT
READ
Yes
acqTriggerStatus: Status of the Analog Input Triggering:
0-> none
1-> present
DEV_SHORT
READ
Yes
bufferDepth: Depth of the buffer per channel (Voltage and Current).
DEV_DOUBLE
READ_WRITE
Yes
frequency: Sampling Frequency for Voltage and Current Acquisition
DEV_DOUBLE
READ_WRITE
Yes
prechargeTimingStatus: Status of the Precharge Timing: coming from LocalTimingSystem:
0 -> none
1 -> present
DEV_SHORT
READ
Yes





Spectrum Attributes
Attribute name
Data Type
X Data Length
Expert
voltageSpectrum: Readback of the Voltage on the Load (out of the Power Supply).
DEV_DOUBLE
10000
No
currentSpectrum: Readback of the Current on the Load (out of the Power Supply).
DEV_DOUBLE
10000
No







ESRF - Software Engineering Group